Air Clamp
2. Do not exceed the capacity of clamp
3. To maintain the unclamping state, supply air pressure 4kg/cm2 or more to the release port.
4. There is ±10% variation in holding and clamping force.
5. Working temperature: 0~120℃
MODEL SELECTION
|
CGA - □ B |
|
|
Capacity of clamp |
4~10 (tons) |
Specification: Clamp Body
|
Model |
CGA-04B |
CGA-06B |
CGA-10B |
|
|
Capacity of clamp |
tons |
4 |
6 |
10 |
|
Operating air pressure |
kg/cm2 |
5 |
||
|
Min. operating air pressure |
kg/cm2 |
4 |
||
|
Holding force (tons) |
Air Pressure 4 kg/cm2 |
4 |
6 |
10 |
|
Air Pressure 0 kg/cm2 |
1.3 |
1.8 |
2.7 |
|
|
Clamping force (tons) |
Air Pressure 5 kg/cm2 |
3.3 |
4.9 |
7.7 |
|
Air Pressure 4 kg/cm2 |
2.8 |
4.2 |
6.5 |
|
|
Air Pressure 0 kg/cm2 |
0.75 |
1.03 |
1.5 |
|
|
Total stroke (X) |
mm |
2.3 |
2.6 |
2.8 |
|
Stroke of clamp (Y) |
mm |
1.1 |
1.2 |
1.2 |
|
Preserved stroke (Z) |
mm |
1.2 |
1.4 |
1.6 |
|
Total volume of cylinder |
Clamp |
265 |
448 |
773 |
|
Unclamp |
248 |
420 |
729 |
|
|
The thickness of template H (min) |
20±0.3 |
25±0.3 |
30±0.3 |
|
| Usable gas | Dry Air | |||
| Working temperature |
0~70℃ V: Heat-resistant type Limit Switch Part: 80℃ or less. |
|||
| Working frequency | Max. 20 Cycles/day | |||
Remark
1. The tolerance of the template thickness(H) should be within ±3mm.
2. Do not exceed the capacity of clamp
3. To maintain the unclamping state, supply air pressure 4kg/cm2 or more to the release port.
4. There is ±10% variation in holding and clamping force.
5. Working temperature: 0~120℃
V: Heat-resistant type. (Limit switch part: 80℃ or less.)
6. Please contact us for more frequent use.
Hot Tags: air clamp, Taiwan air clamp manufacturers, suppliers, factory, Quick Change Mold Clamps, Check Valve Clamp, Injection Mold Clamps, hydraulic clamp, quick mold change system, Mold Clamp
Previous
Check Valve ClampYou Might Also Like
Send Inquiry