Air Clamp
2. Do not exceed the capacity of clamp
3. To maintain the unclamping state, supply air pressure 4kg/cm2 or more to the release port.
4. There is ±10% variation in holding and clamping force.
5. Working temperature: 0~120℃
MODEL SELECTION
|
CGA - □ B |
|
|
Capacity of clamp |
4~10 (tons) |
Specification: Clamp Body
|
Model |
CGA-04B |
CGA-06B |
CGA-10B |
|
|
Capacity of clamp |
tons |
4 |
6 |
10 |
|
Operating air pressure |
kg/cm2 |
5 |
||
|
Min. operating air pressure |
kg/cm2 |
4 |
||
|
Holding force (tons) |
Air Pressure 4 kg/cm2 |
4 |
6 |
10 |
|
Air Pressure 0 kg/cm2 |
1.3 |
1.8 |
2.7 |
|
|
Clamping force (tons) |
Air Pressure 5 kg/cm2 |
3.3 |
4.9 |
7.7 |
|
Air Pressure 4 kg/cm2 |
2.8 |
4.2 |
6.5 |
|
|
Air Pressure 0 kg/cm2 |
0.75 |
1.03 |
1.5 |
|
|
Total stroke (X) |
mm |
2.3 |
2.6 |
2.8 |
|
Stroke of clamp (Y) |
mm |
1.1 |
1.2 |
1.2 |
|
Preserved stroke (Z) |
mm |
1.2 |
1.4 |
1.6 |
|
Total volume of cylinder |
Clamp |
265 |
448 |
773 |
|
Unclamp |
248 |
420 |
729 |
|
|
The thickness of template H (min) |
20±0.3 |
25±0.3 |
30±0.3 |
|
| Usable gas | Dry Air | |||
| Working temperature |
0~70℃ V: Heat-resistant type Limit Switch Part: 80℃ or less. |
|||
| Working frequency | Max. 20 Cycles/day | |||
Remark
1. The tolerance of the template thickness(H) should be within ±3mm.
2. Do not exceed the capacity of clamp
3. To maintain the unclamping state, supply air pressure 4kg/cm2 or more to the release port.
4. There is ±10% variation in holding and clamping force.
5. Working temperature: 0~120℃
V: Heat-resistant type. (Limit switch part: 80℃ or less.)
6. Please contact us for more frequent use.
Hot Tags: air clamp, Taiwan air clamp manufacturers, suppliers, factory
Previous
Check Valve ClampYou Might Also Like
Send Inquiry